H07rn-F Ruber Cable Hrn HD 22.4 S3, IEC 60245-4, DIN VDE 0282 Part 4

FOB Price: Get Latest Price
Min. Order: 1,000 Meters
Port: Ningbo, China
Production Capacity: 2000ton/Month
Payment Terms: L/C, T/T, Western Union, Paypal, Money Gram, Cash

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: H07RN-F
  • Port of Loading: Tianjin, Qingdao, Ningbo, Shanghai, Xiamen, Shenzh
  • Capacity: 2000ton/Month
  • Delivery Length: Accord with The Request
  • Transport Package: Drum
  • Origin: Henan, China
  • Certification: SABS, ISO9001-2008, CQC Certificate, CE , SGS
  • Payment Term: L/C, D/P, D/a ,T/T, M/T, D/D, O/a, C.W.O, C.O.D, C
  • MOQ: 1km
  • Trademark: Jiapu
  • Specification: CE SGS SABS
  • HS Code: 4101962331
Product Description
H07RN-F ruber cable  HRN HD 22.4 S3, IEC 60245-4, DIN VDE 0282 part 4
 HRN HD 22.4 S3, IEC 60245-4, DIN VDE 0282 part 4

Construction:
Conductor: bare or tinned copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295
Insulation: rubber compound on ethylene-propylene basis (EPM, earlier: EPR), i.e. EI4 acc. to DIN VDE 0282 part 1
At some producers resistant textile tape spirally wrapped around each core, acc. DIN VDE 0282 part 4
Sheath:  rubber compound on poly-chloroprene basis (CR), i.e. acc. to. DIN VDE 0282 part 1
At one-layer construction: EM2 compound
At two-layer construction: inner layer EM2 or EM3; external layer EM2
sheath colour: black
Core colour markingacc. to HRN HD 308 S2 / VDE 0293-308   
during installation:  
 -30 °C up to +60 °C
maximal operating temp:   +60 °C

at short circuit of max. 5 s:    up to 200 °C
Nominal voltage:    U/U = 450/500 V
Test voltage:    2500 V 
Alternating current three-phase and single-phase:    
U/U = 476/825 V
Direct current:    U/U = 619/1238 V 
For fixed installation:  
 4D

For running over roller:    7,5D
At winding on drum:    5 -7D
Behaviour in fire:    IEC 60332-1
Ozone resistance:    acc. to DIN VDE 0472 part 805

Workshop:
H07rn-F Ruber Cable Hrn HD 22.4 S3, IEC 60245-4, DIN VDE 0282 Part 4

Shipment:
H07rn-F Ruber Cable Hrn HD 22.4 S3, IEC 60245-4, DIN VDE 0282 Part 4


Specification:

Dimensions - number of cores x conductor cross-section*Construction of individual conductorConductor diameterInsulation thicknessSheath thicknessExternal diameterConductor resistance at 20 CCu weightCable weightPacking
 nominalmax.nominalnominalmin-max.max. approx. 
N x mm2n x mmmmmmmmmmΩ/kmkg/kmkg/km 
1 x 1,530 x 0,251,80,81,45,7 - 7,113,314,457CUT
1 x 2,550 x 0,252,60,91,46,3 - 7,97,982479CUT
1 x 456 x 0,303,21,01,57,2 - 9,04,9538,4100CUT
1 x 1684 x 0,303,91,01,67,9 - 9,83,3057,6135CUT
1 x 1080 x 0,405,11,21,89,5 - 11,91,9196204CUT
1 x 16128 x 0,406,31,21,910,8 - 13,41,21153,6286CUT
1 x 25200 x 0,407,81,42,012,7 - 15,80,780240390CUT
1 x 35280 x 0,409,21,42,214,3 - 17,90,554336523CUT
1 x 50400 x 0,40111,62,416,5 - 20,60,386480699CUT
1 x 70356 x 0,50131,62,618,6 - 23,30,272672950CUT
1 x 95485 x 0,5015,11,82,820,8 - 26,00,2069121202CUT
1 x 120614 x 0,50171,83,022,8 - 28,60,16111521524CUT
1 x 150765 x 0,50192,03,225,2 - 31,40,12914401839CUT
1 x 185944 x 0,50212,23,427,6 - 34,40,10617762184CUT
1 x 2401225 x 0,50242,43,530,6 - 38,30,080123042840CUT
1 x 3001530 x 0,50272,63,633,5 - 41,90,064128803413CUT
1 x 4002034 x 0,50312,83,837,4 - 46,80,048638404600CUT
1 x 5001768 x 0,60353,04,041,3 - 52,00,038448006000CUT
 
2 x 132 x 0,201,50,81,37,7 - 10,019,519,2105CUT
2 x 1,530 x 0,251,80,81,58,5 - 11,013,328,8136c.100
2 x 2,550 x 0,252,60,91,710,2 - 13,17,9848190c.100
2 x 456 x 0,303,21,01,811,8 - 15,14,9576,8271CUT
2 x 684 x 0,303,91,02,013,1 - 16,83,30115,2372CUT
2 x 1080 x 0,405,11,2-17,7 - 22,61,91192643CUT
2 x 16128 x 0,406,31,2-20,2 - 25,71,21307,2810CUT
2 x 25200 x 0,407,81,4-24,3 - 30,70,7804801160CUT
H07RN-F
3 G 132G0,201,50,81,48,3 - 10,719,528,8125CUT
3 G 1,530G0,251,80,81,69,2 - 11,913,343,2162c.100
3 G 2,550G0,252,60,91,810,9 - 14,07,9872229c.100
3 G 456G0,303,21,01,912,7 - 16,24,95115,2329CUT
3 G 684G0,303,91,02,114,1 - 18,03,30172,8452CUT
3 G 1080G0,405,11,23,319,1 - 24,21,91288776CUT
3 G 16128G0,406,31,23,521,8 - 27,61,21460,81058CUT
3 G 25200G0,407,81,43,826,1 - 33,00,7807201473CUT
3 G 35280G0,409,21,44,129,3 - 37,10,55410081728CUT
3 G 50400G0,40111,64,534,1 - 42,90,38614402302CUT
3 G 70356G0,50131,64,838,4 - 48,30,27220163400CUT
3 G 95485G0,5015,11,85,343,3 - 54,00,20627364450CUT
3 G 120614G0,50171,85,647,4 - 60,00,16134565180CUT
3 G 150765G0,50192,06,052,0 - 66,00,12943206500CUT
H07RN-F
4 G 132G0,201,50,81,59,2 - 11,919,538,4163CUT
4 G 1,530G0,251,80,81,710,2 - 13,113,357,6197c.100
4 G 2,550G0,252,60,91,912,1 - 15,57,9896279c.100
4 G 456G0,303,21,02,014,0 - 17,94,95153,6402CUT
4 G 684G0,303,91,02,315,7 - 20,03,30230,4561CUT
4 G 1080G0,405,11,23,420,9 - 26,51,91384935CUT
4 G 16128G0,406,31,23,623,8 - 30,11,21614,41286CUT
4 G 25200G0,407,81,44,128,9 - 36,60,7809601692CUT
4 G 35280G0,409,21,44,432,5 - 41,10,55413442266CUT
4 G 50400G0,40111,64,837,7 - 47,50,38619203021CUT
4 G 70356G0,5013,11,65,242,7 - 54,00,27226884121CUT
4 G 95485G0,5015,11,85,948,4 - 61,00,20636485361CUT
4 G 120614G0,50171,86,053,0 - 66,00,16146086546CUT
4 G 150765G0,50192,06,558,0 - 73,00,12957608095CUT
4 G 185944G0,50212,27,064,0 - 80,00,10671049652CUT
4 G 2401225G0,50242,4 72,0 - 91,00,0801921612614CUT
4 G 3001530G0,50272,6 80,0 - 1010,06411152015200CUT
H07RN-F
5 G 132 x 0,201,50,81,611,619,548168CUT
5 G 1,530 x 0,251,80,81,811,2 - 14,413,372234c.100
5 G 2,550 x 0,252,60,92,013,3 - 17,07,98120348c.100
5 G 456 x 0,303,21,02,215,6 - 19,94,95192470CUT
5 G 684 x 0,303,91,02,517,5 - 22,23,30288620CUT
5 G 1080 x 0,405,11,23,622,9 - 29,11,914801155CUT
5 G 16128 x 0,406,31,23,926,4 - 33,31,217681460CUT
5 G 25200 x 0,407,81,44,432,0 - 40,40,78012002380CUT
5 G 35280 x 0,409,21,44,537 - 420,55416802716CUT
5 G 50400 x 0,40111,65,043 - 470,38624003809CUT
5 G 70356 x 0,5013,11,65,545 - 500,27233605087CUT
 
7 G 1,530 x 0,251,80,82,514 - 15,713,3100,8335CUT
12 G 1,530 x 0,251,80,82,917,6 - 22,413,3172,8560CUT
19 G 1,530 x 0,251,80,82,522,5 - 26,613,3273,6795CUT
24 G 1,530 x 0,251,80,83,524,3 - 30,713,3345,61000CUT
36 G 1,530 x 0,251,80,83,833,013,3518,4 CUT
H07RN-F
7 G 2,550 x 0,252,60,92,716,5 - 18,27,98168520CUT
12 G 2,550 x 0,252,60,93,118,5 - 22,57,98288760CUT
19 G 2,550 x 0,252,60,93,524,6 - 317,984561075CUT
24 G 2,550 x 0,252,60,93,928,8 - 36,47,985761390CUT
36 G 2,550 x 0,252,60,94,337,57,98864 CU


Certification:
H07rn-F Ruber Cable Hrn HD 22.4 S3, IEC 60245-4, DIN VDE 0282 Part 4


FAQ:
 1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China

2. What kinds of products does Jiapu Cable manufacture?

1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;

2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;

3)PVC Insulated (Flexible ) Wire ;

4) PVC Insulated and Sheathed (Armoured) Power Cable;

5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;

6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;

3. What kind of certifications do you have?

SABS, CE, ISO9001-2000, SGS

4.Which markets do you involve mainly in?

Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.

5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.

6. What is the min.order quantity ?
The power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.

7. What is the production capacity per week or per month ?

For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.

8. Do you supply the customers with installation service in foreign country ?

We don't have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for