Gold Member Since 2008
Audited Supplier
Henan Jiapu Cable Co., Ltd.

Overhead Cable, XLPE Insulated Overhead ABC Cable, Overhead ABC Cable manufacturer / supplier in China, offering Aluminium Conductor XLPE Insulated Overhead ABC Cable, PVC Sheathed Power Cable (VV/VLV/VV22/VV32) , Screened Rubber Sheathed Movable and Flexible Mine Cables. and so on.

(/ )

Supplier Homepage Product Overhead Insulated Cable Others Overhead Insulated Cable Aluminium Conductor XLPE Insulated Overhead ABC Cable

Aluminium Conductor XLPE Insulated Overhead ABC Cable

FOB Price: US $1 / Meter
Min. Order: 1,000 Meters
Min. Order FOB Price
1,000 Meters US $1/ Meter
Get Latest Price
Port: Shanghai, China
Production Capacity: 5000 Kilometers/Month
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram, Cash

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: ABC
  • Conductor Type: Stranded
  • Conductor Material: Aluminum
  • Insulation Material: XLPE
  • Brand: Henan Jiapu
  • Jacket: None
  • Cores: 1-4 Cores
  • Trademark: Jiapu
  • Specification: IEC ASTM BS DIN, Any standard
  • HS Code: 4101962331
  • Type: Insulated
  • Application: Overhead
  • Sheath Material: PVC
  • Certification: ISO9001, CE, SABS
  • Voltage: Low
  • Armor: None
  • Voltage Rating: 0.6/1kv,10kv
  • Transport Package: Wooden Drum or Wooden&Steel Drum
  • Origin: Henan, China
Product Description
Aluminium Conductor XLPE Insulated Overhead ABC Cable

Applications:
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connect to the service entrance cable. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75° C for PE insulated Conductors or 90° C for crosslinked polyethylene (XLPE) insulated conductors.

Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.

Installation:
For service at 600 volts or less (phase to phase) at a maximum conductor temperature of 75 0C for Polyethylene insulation or 90 0C for Cross-Linked (XLPE) insulation

Specifications
Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
B-230 Aluminum Wire, 1350-H19 for electrical purposes
B-231 Aluminum Conductors, concentric-lay-stranded
B-232 Aluminum Conductors, concentric-lay-stranded, coated steel reinforced(ACSR)
B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
B-498 Zinc-coated Steel Core Wire for Aluminum Conductors, steel reinforced(ACSR/AZ)

Triplex Service Drop cable meets or exceeds all aplicable requierements of
ANSI/ICEA S-76-474.

Remarks:
1) Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent
Resistivity per ASTMB-399 for 6201.
2) Conductor temperature of 90° C for XLPE 75° C for PE; Ambient temperatures of
40° C; Emissivity 0.9; 2ft. /sec/wind in sun.

The advantages of our company:

1) Our company is a professional supplier of various kinds of cables for over 10 years.
2) The quality of our products are guaranteed.
3) The price is averagely 10%~20% lower than the other competitors
4) Huge Inventory Allows Us To Ship Your Order Immediately
5) Our employees are all capable and professinal. They can offer you the Prompt Courteous Service.
6) We ship worldwide.

Specification:
(1)Self-supporting
PhasePhasePhaseApprox.Overall DiameterMax. D.C. Resistance of Conductor at 20ºC
AAC+UV-XLPECompact ConductorUV-XLPE Insulation
No.X Normal Cross Section of CoresNo.of Al WiresOverall DiameterNormal ThicknessMin.Diameter
No. X mm2-mmmmmmmmmmohm/km
1 X 1074.051.00.86.056.053.08
1 X 1674.81.20.987.27.201.91
1 X 25761.20.988.48.401.20
1 X 3577.01.41.169.89.800.868
1 X 5078.31.41.1611.111.100.641
1 X 70199.81.41.1612.612.600.443
1 X 951911.61.61.3414.814.800.320
1 X 12019131.61.3416.216.200.253
1 X 1501914.61.81.5218.218.200.206
1 X 1853616.22.01.7020.220.200.164
1 X 2403618.42.21.8822.822.800.125
2 X 1074.051.00.86.0512.103.08
2 X 1674.81.20.987.214.401.91
2 X 25761.20.988.416.801.20
2 X 3577.01.41.169.819.600.868
2 X 5078.31.41.1611.122.200.641
2 X 70199.81.41.1612.625.200.443
2 X 951911.61.61.3414.829.600.320
2 X 12019131.61.3416.232.400.253
2 X 1501914.61.81.5218.236.400.206
2 X 1853616.22.01.7020.240.400.164
2 X 2403618.42.21.8822.845.600.125
3 X 1074.051.00.86.0513.073.08
3 X 1674.81.20.987.215.551.91
3 X 25761.20.988.418.141.20
3 X 3577.01.41.169.821.170.868
3 X 5078.31.41.1611.123.980.641
3 X 70199.81.41.1612.627.220.443
3 X 951911.61.61.3414.831.970.320
3 X 12019131.61.3416.234.990.253
3 X 1501914.61.81.5218.239.310.206
3 X 1853616.22.01.7020.243.630.164
3 X 2403618.42.21.8822.849.250.125
4 X 1074.051.00.86.0514.643.08
4 X 1674.81.20.987.217.421.91
4 X 25761.20.988.420.331.20
4 X 3577.01.41.169.823.720.868
4 X 5078.31.41.1611.126.860.641
4 X 70199.81.41.1612.630.490.443
4 X 951911.61.61.3414.835.820.320
4 X 12019131.61.3416.239.200.253
4 X 1501914.61.81.5218.244.040.206
4 X 1853616.22.01.7020.248.880.164
4 X 2403618.42.21.8822.855.180.125
(2) Phase + Neutral
PhaseNeutralPhaseNeutralApprox.Overall DiameterMax. D.C. Resistance of Conductor at 20ºC
AAC+UV-XLPEAAACCompact ConductorUV-XLPE InsulationConductor
PhaseNeutral
No.X Normal Cross Section of CoresNo.X Normal Cross Section of CoresNo.of Al.WireOverall Dia.Normal ThicknessMin.No./Dia. of Al Alloy Wire
No. X mm2No. X mm2-mm   mmMin.No./mm     mmohm/kmohm/km
1 X 161 X 1674.81.20.987/1.7012.301.912.217
1 X 251 X 25761.20.987/2.1014.701.201.393
1 X 351 X 3577.01.41.167/2.5017.300.8681.007
1 X 501 X 5078.31.41.167/3.0020.100.6410.744
1 X 701 X 70199.81.41.167/3.5023.100.4430.514
1 X 951 X 951911.61.61.3419/2.5027.300.3200.371
1 X 1201 X 12019131.61.3419/2.8030.200.2530.294
1 X 1501 X 1501914.61.81.5237/2.2533.950.2060.239
1 X 1851 X 1853616.22.01.7037/2.5037.700.1640.190
1 X 2401 X 2403618.42.21.8861/2.2543.050.1250.145
2 X 161 X 1674.81.20.987/1.7014.041.912.217
2 X 251 X 25761.20.987/2.1016.631.201.393
2 X 351 X 3577.01.41.167/2.5019.510.8681.007
2 X 501 X 5078.31.41.167/3.0022.460.6410.744
2 X 701 X 70199.81.41.167/3.5025.700.4430.514
2 X 951 X 951911.61.61.3419/2.5030.310.3200.371
2 X 1201 X 12019131.61.3419/2.8033.410.2530.294
2 X 1501 X 1501914.61.81.5237/2.2537.550.2060.239
2 X 1851 X 1853616.22.01.7037/2.5041.690.1640.190
2 X 2401 X 2403618.42.21.8861/2.2547.410.1250.145
3 X 161 X 1674.81.20.987/1.7016.151.912.217
3 X 251 X 25761.20.987/2.1019.061.201.393
3 X 351 X 3577.01.41.167/2.5022.320.8681.007
3 X 501 X 5078.31.41.167/3.0025.590.6410.744
3 X 701 X 70199.81.41.167/3.5029.220.4430.514
3 X 951 X 951911.61.61.3419/2.5034.420.3200.371
3 X 1201 X 12019131.61.3419/2.8037.870.2530.294
3 X 1501 X 1501914.61.81.5237/2.2542.560.2060.239
3 X 1851 X 1853616.22.01.7037/2.5047.250.1640.190
3 X 2401 X 2403618.42.21.8861/2.2553.630.1250.145
(3) Phase + Neutral + Service Connection
PhaseNeutralService ConnectionPhaseNeutral    Service ConnectionApprox.Overall Diameter of Bundled Cable
AAC+UV-XLPEAAAC+UV-XLPEAAC+UV-XLPEConductorUV-XLPEConductorUV-XLPECompact ConductorUV-XLPE
No.X Normal Cross Section of CoresNo.X Normal Cross Section of CoresNo.X Normal Cross Section of CoresNo. of Al. WireOverall Dia.Normal
Thickness
No./Dia. of Al. WireNormal
Thickness
No. of Al. WireOverall Dia.Normal
Thickness
No. X mm2No. X mm2No. X mm2-mmmmmmmmNo./mmmmmmmm
3 X 161 X 501 X 1674.81.27/3.01.474.81.226.2
3 X 251 X 501 X 16761.27/3.01.474.81.228.6
3 X 351 X 501 X 1677.01.47/3.01.474.81.231.4
3 X 501 X 501 X 1678.31.47/3.01.474.81.234
3 X 701 X 501 X 16199.81.47/3.01.474.81.237
3 X 951 X 501 X 161911.61.67/3.01.474.81.241.4
3 X 1201 X 501 X 1619131.67/3.01.474.81.244.2
3 X 161 X 502 X 1674.81.27/3.01.474.81.226.2
3 X 251 X 502 X 16761.27/3.01.474.81.228.6
3 X 351 X 502 X 1677.01.47/3.01.474.81.231.4
3 X 501 X 502 X 1678.31.47/3.01.474.81.234
3 X 701 X 502 X 16199.81.47/3.01.474.81.237
3 X 951 X 502 X 161911.61.67/3.01.474.81.241.4
3 X 1201 X 502 X 1619131.67/3.01.474.81.244.2
Send your message to this supplier
Avatar
Miss Sara Tang
Marketing Manager
*From:
To: Miss Sara Tang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now