Basic Info
  • Model NO.: VV/VLV/VV22/VV32
  • Voltage: Low and Medium Voltage Cable
  • Insulation Material: PVC
  • Trademark: Jiapu
  • Origin: Henan China
  • Application: Construction, Underground
  • Current: AC Cable
  • Certification: ISO, CE, SABS
  • Specification: IEC GB BS ASTM Any standard
  • HS Code: 4101962331
Product Description
Aluminum(Copper)/PVC insulation /PVC sheath

This series includes:
Copper (aluminum) core, PVC insulated and sheathed power cables
Copper (aluminum) core, PVC insulated, PE sheathed power cables
Copper (aluminum) core, PVC insulated, steel tape armoring PVC sheathed power cables
Copper (aluminum) core, PVC insulated, steel tape armoring, PE sheathed power cables
Copper (aluminum) core, PVC insulated, steel wire armoring, PVC sheathed power cables
Copper (aluminum) core, PVC insulated, steel wire armoring, PE sheathed power cables

This series is mainly laid indoor, cable slot, direct burial, channel, mining well and water condition. This series has the following characteristics: The max. Rated temperature of the conductor is 70 degree. The max. Temperature of the conductor of the cables cannot exceed 160 degrees.

The cables can be laid without the limit of fall with enough mechanical pull, but the single core cable cannot be laid in iron tube or cannot be fixed by circled iron tools around the cables.

The laying temperature of cables should not be lower than 0 degree, When the ambient temperature is under 0 degree, the cables should be heated up to 0 degree higher with certain methods.

Rated voltage: 0.6/1kV, 3.6/6kV* Number of cores: 1-6

Standarded: IEC, BS, DIN, GB, any standard

Remarks: Including products for flame retardant, fire resistant and termite-proof

Packing: Wooden drum, steel wooden drum

PVC Sheathed Power Cable (VV/VLV/VV22/VV32)
Workshop
PVC Sheathed Power Cable (VV/VLV/VV22/VV32)
Shipment
PVC Sheathed Power Cable (VV/VLV/VV22/VV32)
FAQ

1. How many years has Henan Jiapu Cable Group been in production?

Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China

 

2. What kinds of products does Jiapu Cable manufacture?

1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;

2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;

3)PVC Insulated (Flexible ) Wire ;

4) PVC Insulated and Sheathed (Armoured) Power Cable;

5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;

6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;

 

3. What kind of certifications do you have?

SABS, CE, ISO9001-2000, SGS

 

4.Which markets do you involve mainly in?

Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.

 

5. Which standards do you comply with when you produce the electrical wires and cables ?

We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.

 

6. What is the min.order quantity ?

It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.

 

7. What is the production capacity per week or per month ?

For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.

 

8. Do you supply the customers with installation service in foreign country ?

We don't have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.


1)600/1000V, Single Core, Circular Compacted Al or Cu/PVC/PVC Unarmoured or Armoured Power Cable
Cross Section  of Conductor No. of Wires Thickness of Insulation                     Unarmoured                                                               Armoured
Thickness of Sheath Overall Dia. Approx. Net Weight Thickness of Bedding Thickness of Al Tape Thickness of Sheath Overall Dia. Approx. Net Weight
Al Conductor Cu Conductor Al Conductor Cu Conductor
mm 2 - mm mm mm kg/km kg/km mm mm mm mm kg/km kg/km
1.5 1 0.8 1.4 5.8 - 51 - - - - - -
2.5 1 0.8 1.4 6.2 - 64 - - - - - -
4 1 1 1.4 7.1 - 88 - - - - - -
6 7 1 1.4 7.8 78 114 - - - - - -
10 7 1 1.4 8.6 96 159 1 0.5 1.8 13.4 234 295
16 7 1 1.4 9.6 123 222 1 0.5 1.8 14.4 274 370
25 7 1.2 1.4 11.2 172 328 1 0.5 1.8 16 344 496
35 7 1.2 1.4 12.2 209 428 1 0.5 1.8 17 393 606
50 19 1.4 1.4 13.9 271 565 1 0.5 1.8 18.7 478 764
70 19 1.4 1.5 15.9 356 818 1 0.5 1.8 20.5 582 1020
95 19 1.6 1.5 18 471 1041 1 0.5 1.8 22.6 717 1291
120 37 1.6 1.6 19.6 563 1307 1 0.5 1.8 24 822 1545
150 37 1.8 1.6 21.3 684 1592 1 0.5 1.8 25.4 952 1857
185 37 2 1.7 23.9 840 1985 1 0.5 1.8 27.9 1136 2236
240 61 2.2 1.8 27 1071 2533 1 0.5 1.9 31 1404 2877
300 61 2.4 1.9 29.6 1317 3162 1.2 0.5 2.1 34.3 1722 3551
400 61 2.6 2 33.2 1666 4120 1.2 0.5 2.2 37.6 2114 4488
500 61 2.8 2.2 37.5 2089 5163 1.2 0.5 2.3 42.1 2592 5683
630 61 2.8 2.3 41.2 2581 6447 1.4 0.5 2.4 46.3 3184 7060
2)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
Number of Cores                                      Cross-Section of Conductor No. Of Wires Thickness of Insulation Thickness of Sheath Overall Diameter Approx. Net Weight       
Al Conductor Cu Conductor      
          -                    mm 2             - mm mm mm kg/km kg/km      
Three Cores 3x35 16 1.2 1.8 21.9 601 1280      
3x50 18 1.4 1.8 26.5 829 1732      
3x70 18 1.4 1.9 29.2 1067 2367      
3x95 36 1.6 2 32.9 1409 2317      
3x120 36 1.6 2.1 36.2 1705 3983      
3x150 36 1.8 2.2 38.8 2045 4872      
3x185 36 2 2.4 44.8 2596 6077      
3x240 60 2.2 2.6 51.5 3353 7953      
3x300 60 2.4 2.7 54.9 6069 9820      
Four Cores with Reduced Neutral 3x35+16 716 1.2-1 1.8 25.5 764 1107      
3x50+25 18-16 1.4-1.2 1.9 28.7 982 1410      
3x70+35 18-16 1.4-1.2 2 32 1278 1733      
3x95+50 36-18 1.6-1.4 2.2 37.8 1711 2656      
3x120+70 36-18 1.6-1.4 2.3 40.5 2065 3137      
3x150+70 36-18 1.8-1.4 2.4 44.8 2480 3660      
3x185+95 36-36 2-1.6 2.6 49.7 3086 4345      
3x240+120 60-36 2.2-1.6 2.8 56 3894 5441      
3x300+150 60-36 1.4-1.8 2.9 60.3 4834 6494      
Four Cores 4x25 16 1.2 1.8 22.5 644 1286      
4x35 16 1.2 1.8 24.6 799 1696      
4x50 18 1.4 1.8 28.6 1071 2275      
4x70 18 1.4 2 31.6 1387 3120      
4x95 36 1.6 2.1 35.9 1850 4262      
4x120 36 1.6 2.2 38.8 2209 5247      
4x150 36 1.8 2.3 43.1 2714 6483      
4x185 36 2 2.5 48.7 3403 8045      
4x240 60 2.2 2.7 53.6 4290 10422      
4x300 60 2.4 2.9 58.8 5302 12969      
3)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Unarmoured Power Cable      
Number of Cores                                      Cross-Section of Conductor No. Of Wires Thickness of Insulation Thickness of Sheath Overall Diameter Approx. Net Weight         
Al Conductor Cu Conductor        
          -                    mm 2             - mm mm mm kg/km kg/km        
Three Cores 3x10 7 1 1.8 16.6 281 465        
3x16 7 1 1.8 18.7 387 679        
3x25 7 1.2 1.8 22.2 536 996        
3x35 7 1.2 1.8 24.4 665 1311        
3x50 19 1.4 1.9 28.1 863 1729        
3x70 19 1.4 2 32.3 1153 2480        
3x95 19 1.6 2.1 37.1 1563 3301        
3x120 37 1.6 2.3 40.4 1850 4040        
3x150 37 1.8 2.4 43.9 2258 5000        
3x185 37 2 2.5 49.2 2819 6151        
3x240 61 2.2 2.8 55.9 3577 8040        
3x300 61 2.4 3 62.1 4413 9955        
3x400 61 2.6 3.2 69.3 5512 12705        
Four Cores 4x10 7 1 1.8 18.1 343 589        
4x16 7 1 1.8 20.5 487 874        
4x25 7 1.2 1.8 24.3 677 1291        
4x35 7 1.2 1.8 26.8 821 1681        
4x50 19 1.4 2 31.2 1118 2273        
4x70 19 1.4 2.1 35.8 1494 3264        
4x95 19 1.6 2.3 41.2 1993 4312        
4x120 37 1.6 2.4 44.8 2370 5291        
4x150 37 1.8 2.5 48.7 2959 6615        
4x185 37 2 2.7 54.7 3601 8044        
4x240 61 2.2 3 62.1 4596 10547        
4x300 61 2.4 3.2 69.1 5614 13004        